Siemens SIPROTEC HTTP(S)
Use this strategy on SIPROTEC 4 or SIPROTEC 5 devices that expose the HTTP(S) protocol.
Credentials
This strategy requires credentials with scope http-sp.
Device-side ports
TCP/4443
Arc availability
Since 1.15.0
Guardian availability
Since 21.8.0
Collected items
This strategy enriches the monitored nodes with these items:
- Firmware version
- Label
- Product name
- Serial number
- Vendor
- Node property: assigned_fct_points
- Node property: configuration_version
- Node property: mode
- Node property: mounting_position_1
- Node property: mounting_position_2
- Node property: port_e
- Node property: product code
- Node property: product_code
- Node property: short_product_code
- Node property: siprotec_version
- Node property: system_time
Note: The collected items may vary depending on the device and its configuration.
Asset merging capabilities
The strategy does not feature asset merging capabilities.
Progressive mode queries
This strategy can use this progressive-mode query to identify the targeted nodes:
- nodes | where product_name include? "siprotec 4" OR product_name include? "siprotec 5" | where vendor include? "siemens"