Mitsubishi Electric MELSOFT
Use this strategy on Mitsubishi Electric devices that expose the MELSOFT protocols, such as: GOT1000, GOT2000, Q-Series, iQ-R Series.
Credentials
This strategy does not require credentials.
Device-side ports
UDP/5001, TCP/5002, UDP/5006, TCP/5007, TCP/5014, TCP/5015
Arc availability
Since 1.7.0
Guardian availability
Since 21.8.0
Discovery trigger
Nodes discovered through the melsoft discovery strategy will be automatically smart-polled by this strategy.
Collected items
This strategy enriches the monitored nodes with these items:
- Device type
- Firmware version
- Hardware modules
- MAC address
- Product name
- Serial number
- Vendor
- Node property: melsoft/gt_designer3_version
- Node property: melsoft/network_number
- Node property: melsoft/station_number
Note: The collected items may vary depending on the device and its configuration.
Asset merging capabilities
The strategy can merge nodes into an asset.
Progressive mode queries
This strategy can use this progressive-mode query to identify the targeted nodes: nodes | where vendor == "Mitsubishi Electric" OR mac_vendor == "Mitsubishi Electric" OR protocols include? melsoft | where roles include? producer OR roles include? HMI
Configuration parameters
Use the following command to apply a configuration parameter:
conf.user configure smart_polling_and_discovery strategy melsoft <parameter> <value>
inter_session_delayDelay in milliseconds between polling sessions for the same device
Default:
1000cc_link_ie_crawled_devices_limitMaximum number of CC-Link IE devices enumerated per scan
Default:
1000reuse_tcp_sessionsWhether to reuse TCP sessions across polling iterations
Default:
trueenable_udpEnable UDP transport in addition to TCP for Q Series and iQ-R Series devices
Default:
false