Supported file types

Supported configuration and project file types for import in Central Management Console (CMC).

Table 1. Supported file types
Supported file type Notes
Allen-Bradley (.l5x) Imported fields are: ip, firmware version, product name, modules (i.e. port, address, product code, firmware version, product name, vendor).
Emerson Ovation XML (.htm, .html) Imported fields are: Vendor, Product Name, Serial Number, OS, FW, Installed software, hotfixes, Ovation specific hotfixes, Hardware components, and redundancy partner information.
Honeywell TDS (.txt, .zip) Imported fields are: label, vendor
IEC 61850 SCL/SCD (.scd, .icd, .cid) Imported file types are: ip, VLAN, product name, asset type, vendor, AppID, data model Note: Importing this file changes the knowledge of the IEC 61850 data model in use in the system, thus improving Guardian's ability to accurately extract variables. Existing variables related to this protocol are deleted to avoid inconsistencies with those extracted from traffic after the import.
Mitsubishi Electric (.gxw, .gx3) Imported fields are: ip, vendor, type, hardware components
Profinet IOCM (.xml) Imported fields are: modules (i.e. slot, subslot, vendor, software release, hardware release). Note: It might also extract variables.
Rockwell Harmony (.conf, .rsx, .rsh) Imported fields are: ip, product name
Siemens AML (.aml) Imported fields are: ip, mac address, vendor, product name, label, modules (i.e. rack, slot, subslot, product code, module code).
Siemens (.cfg) Imported fields are: ip, mac address, vendor, product name, label, modules (i.e. rack, slot, subslot, product code, module code).
Triconex (.pt2) Imported fields are: ip, label, vendor
Yokogawa CENTUM VP (.gz, .zip) Imported fields are: ip, label, vendor, product name, modules (i.e. slots, each with vendor, product name, firmware version). Note: You need to create a ZIP file that includes: *.edf, /ETC/SystemRevisionInf.txt, project.atr